and evaluation and production sites where NVH & shock quality turnkey testing is to be performed.
Item | function |
---|---|
Test | Fully Automatic Control by protocol |
Setting Test Code for each Channel | |
Time Domain Test Algorithm (rms, peak, crest factor, time, pattern) | |
Frequency Domain Test Algorithm (band, peak, OA, curve) | |
Test Criteria | Fixed Limit |
Learned Limit by Learning Process | |
Triggering | Button, Keyboard / Serial Protocol Triggering |
Analog Level Triggering | |
Timer Triggering for Durability Test | |
RPM Triggering | |
Database | Auto Test Result Save |
Statistical Data Processing | |
Chart | Auto Test Result Save |
Statistical Data Processing | |
Signal Processing | Integration & Derivative (Time & Frequency Domain) |
A - Weighting | |
Report | Test Result Sheet, Report Form Output |
Data Viewer | SVA Viewer |
Scale Linear, Log, dB |
Test | |
---|---|
Function | Fully Automatic Control by protocol |
Setting Test Code for each Channel | |
Time Domain Test Algorithm (rms, peak, crest factor, time, pattern) | |
Frequency Domain Test Algorithm (band, peak, OA, curve) | |
Test Criteria | |
Function | Fixed Limit |
Learned Limit by Learning Process | |
Triggering | |
Function | Button, Keyboard / Serial Protocol Triggering |
Analog Level Triggering | |
Timer Triggering for Durability Test | |
RPM Triggering | |
Database | |
Function | Auto Test Result Save |
Statistical Data Processing | |
Chart | |
Function | Auto Test Result Save |
Statistical Data Processing | |
Signal Processing | |
Function | Integration & Derivative (Time & Frequency Domain) |
A - Weighting | |
Report | |
Function | Test Result Sheet, Report Form Output |
Data Viewer | |
Function | SVA Viewer |
Scale Linear, Log, dB |
Item | specification |
---|---|
Number of Channel | 4 simultaneously sampled(8ch option) |
Resolution | 24bits |
Maximum Sampling Rate | 51.2kHz |
Maximum Frequency Span | 40kHz |
Minimum Frequency Span | 200Hz |
FFT Length | 2,048 / 4,096 / 8,192 / 16,384 |
Effective Frequency Line | 800 / 1,600 / 3,200 / 6,400 |
Dynamic Range | Minimum 110dB (normal 120dB) |
Input Range | +/-10V (Fixed) |
Signal Coupling | AC, DC, ICP(4mA) |
Number of Channel | |
---|---|
Spec | 4 simultaneously sampled(8ch option) |
Resolution | |
Spec | 24bits |
Maximum Sampling Rate | |
Spec | 51.2kHz |
Maximum Frequency Span | |
Spec | 40kHz |
Minimum Frequency Span | |
Spec | 200kHz |
FFT Length | |
Spec | 2,048 / 4,096 / 8,192 / 16,384 |
Effective Frequency Line | |
Spec | 800 / 1,600 / 3,200 / 6,400 |
Dynamic Range | |
Spec | Minimum 110dB (normal 120dB) |
Input Range | |
Spec | +/-10V (Fixed) |
Signal Coupling | |
Spec | AC, DC, ICP(4mA) |
-
01
Machining and assembly quality check
Hardware
-
Product Configuration
-
Axles
-
Manual Transmission
-
Auto Transmission
Software
-
-
02
Speed variability (order tracking) test
-
-
Analysis results
-
-
03
Actuating force (shift force) quality check
-
-
04
Valve quality check
Hardware
-
Sync-VNT system composition
Software
-